pH 80+ DHS Bench Meter with pH electrode XS standard T-BNC

pH 80+ DHS Bench Meter

pH 80+ DHS Bench Meter with pH electrode XS standard T-BNC

R20,845.00 Excl. VAT

In stock

R20,845.00 Excl. VAT

pH 80 PRO kit with stirrer and pH electrode XS STANDARD T BNC DHS, cable S7/BNC, temperature probe NT55, colored pH buffer solutions pH 7 and pH 4, soft keypad, electrode arm, power supply, and accessories. Lead time is 4 weeks.

Availability: Available on backorder SKU: XSI/50101392 Categories: ,
View cart

Description

pH 80+ DHS Bench Meter

pH – mV – ION – Temperature – GLP – GMP – Data Logger

  • pH 80+ DHS kit with STIRRER and pH electrode XS STANDARD T-BNC DHS, temperature probe NT 55, cable S7/BNC 1m, colored buffer solutions pH 7 and pH 4, soft keypad, electrode holder, power supply, and accessories.

Main features

  • Selectable resolution: 0,1/0,01/0,001 pH
  • Simultaneous display of pH / mV / ISE and temperature
  • Analogic view with alarm MIN/MAX
  • GLP and IQ-OQ manual available
  • 5 points Automatic calibration, auto recognition of USA/NIST/DIN buffer solutions
  • 5 points Manual calibration (pH buffers defined by the user)
  • 5 points Automatic calibration with Ion (ISE) electrode
  • Wide colored display with indication of Calibration standards used and measurement’s stability
  • Memory recall of the last calibration, date, and time, and information about the conditions of the electrode
  • Calibration Timer: set the frequency of calibration for high-quality measurements
  • Stability measure filter (Tit – Medium – High) for high accuracy of measurements
  • Alphanumeric password for calibration management and data memory delete with soft keypad included
  • Stirrer plate included (in stirrer version)
  • Indication of stability with an icon
  • Non-volatile memory holds up to 1000 data points, with date and time, in automatic (Data logger) or manually, downloadable on PC
    with the free software “DataLink” or printable
  • Multilanguage menu setup
  • Quick online manual
  • 2 USB ports for data PC downloading and for an external keyboard are included
  • RS232 port for printer connection

pH 80+ DHS Specifications

  • pH measuring range: 2…20
  • Resolution/accuracy: 0.1 / 0.01 / 0.001 / ±0,002
  • Calibration points: 1…5
  • Buffer auto recognition: USA, NIST, DIN, 5 editable user buffers
  • Indication of calibration points: Yes
  • GLP Calibration: Yes, with date and time
  • Indication of conditions of the electrode: Yes, icon and graph
  • Calibration timer with alarm: Yes
  • Stability filter: Tit – Medium – High
  • Alarm settings: MIN-MAX
  • mV measuring range (redox) / Resolution: ± 2000 / 0.1 / 1
  • Ion measuring range: 0,001…19999 ppm
  • Units: mol/L – mg/L – g/L
  • Calibration points: 2…5
  • Temperature measuring range: -20…+120 °C
  • Resolution / Accuracy: 0.1 / ±0,5 °C
  • Temperature compensation: Automatic or Manual 0…100 °C
  • GLP System: Yes
  • Password: Yes, alphanumeric
  • Memory: MAN/AUTO 1000 data, with date and time
  • Display: Multicolor dot matrix, with icons, digital view, or analog view
  • Input: BNC, Cinch/RCA (ATC), RS 232 for printer, USB for PC, and USB for external keyboard
  • Selectable languages: 8 languages
  • Online manual: Yes
  • Magnetic stirrer: Yes (optional)
  • Speed control: 0…3000 rpm
  • IP protection: IP 54
  • Power supply: AC/DC adaptor 12V / 1000mA
  • Dimensions (cm): 16.5 × 19.5 × 6.8 cm
  • Weight (kg): 1.05 kg

DHS Digital High Sensor

Digital High Sensors are the new pH sensors with an internal chip that stores parameters, date of last calibration, model, and production batch of the electrode. In the instruments, pH8+ DHS and pH 80+ DHS, a special chip with the same technology is inserted. After connecting the pH DHS sensor to the instrument, all the data stored in the sensor chip is automatically transferred to the instrument. The display will show on a screen: DHS, sensor model, production batch, date, and hour of the last calibration.

After a new calibration of the DHS electrode, the data is automatically stored in the electrode chip. Let’s move this electrode to another DHS-enabled instrument. We can start working immediately and with extreme security, as the data from the last calibration will automatically be transferred and used for pH measurements.

New DHS pH sensors do not have an internal battery, so they can be stored like a normal pH electrode and do not require special connectors; instead, they use a standard BNC connector.

Many manufacturers using digital sensors have developed dedicated meters for these sensors. This imposes a full range of digital sensors for a variety of applications or lab requirements. Our research and development team has designed this new line of instruments to work with the new DHS digital sensors and the normal analog pH sensors, all brands, which can be connected to the same pH meter. From now on, the pH measurement will be simpler.

Additional information

Weight 2 kg
Dimensions 20 × 20 × 10 cm